Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 289
Filtrar
1.
Otol Neurotol ; 45(4): e271-e280, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38346807

RESUMO

OBJECTIVES: The aim of this study is to improve our understanding of the mechanics involved in the insertion of lateral wall cochlear implant electrode arrays. DESIGN: A series of 30 insertion experiments were conducted by three experienced surgeons. The experiments were carried out in a previously validated artificial temporal bone model according to established soft surgery guidelines. The use of an in vitro setup enabled us to comprehensively evaluate relevant parameters, such as insertion force, intracochlear pressure, and exact electrode array position in a controlled and repeatable environment. RESULTS: Our findings reveal that strong intracochlear pressure transients are more frequently caused during the second half of the insertion, and that regrasping the electrode array is a significant factor in this phenomenon. For choosing an optimal insertion speed, we show that it is crucial to balance slow movement to limit intracochlear stress with short duration to limit tremor-induced pressure spikes, challenging the common assumption that a slower insertion is inherently better. Furthermore, we found that intracochlear stress is affected by the order of execution of postinsertion steps, namely sealing the round window and posterior tympanotomy with autologous tissue and routing of the excess cable into the mastoid cavity. Finally, surgeons' subjective estimates of physical parameters such as speed, smoothness, and resistance did not correlate with objectively assessed measures, highlighting that a thorough understanding of intracochlear mechanics is essential for an atraumatic implantation. CONCLUSION: The results presented in this article allow us to formulate evidence-based surgical recommendations that may ultimately help to improve surgical outcome and hearing preservation in cochlear implant patients.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Implante Coclear/métodos , Cóclea/cirurgia , Janela da Cóclea/cirurgia , Osso Temporal/cirurgia , Eletrodos Implantados
2.
J Vis Exp ; (203)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38345253

RESUMO

The utilization of endoscopes in modern otology has evolved from diagnostic purposes to the development of exclusive endoscopic ear surgery. This technique offers a panoramic view of the middle ear and provides an optimal magnification of the oval window region, the stapes' suprastructure, and the footplate, allowing great precision in prosthesis positioning during ossiculoplasty (OPL). Various techniques for ossicular chain reconstruction have been described in the literature. Either autologous or synthetic materials can be used for reconstruction. The use of a patient's own tissue minimizes the risk of implant rejection or extrusion of the prosthesis through the tympanic membrane. On the other hand, synthetic materials like titanium are light and rigid and do not require time-consuming prosthesis remodeling. The main objective of this article is to present a comprehensive step-by-step guide that serves as a surgical manual for exclusive endoscopic OPL. This guide will explain various forms of OPL using synthetic and autologous materials. The goal is to provide a comprehensive understanding of the various surgical techniques and support the integration into clinical practice.


Assuntos
Orelha Média , Prótese Ossicular , Humanos , Orelha Média/cirurgia , Bigorna , Estribo , Implantação de Prótese , Resultado do Tratamento , Estudos Retrospectivos
3.
Commun Biol ; 7(1): 157, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38326549

RESUMO

The characterization of the vibrations of the middle ear ossicles during sound transmission is a focal point in clinical research. However, the small size of the structures, their micrometer-scale movement, and the deep-seated position of the middle ear within the temporal bone make these types of measurements extremely challenging. In this work, dynamic synchrotron-based X-ray phase-contrast microtomography is used on acoustically stimulated intact human ears, allowing for the three-dimensional visualization of entire human eardrums and ossicular chains in motion. A post-gating algorithm is used to temporally resolve the fast micromotions at 128 Hz, coupled with a high-throughput pipeline to process the large tomographic datasets. Seven ex-vivo fresh-frozen human temporal bones in healthy conditions are studied, and the rigid body motions of the ossicles are quantitatively delineated. Clinically relevant regions of the ossicular chain are tracked in 3D, and the amplitudes of their displacement are computed for two acoustic stimuli.


Assuntos
Imageamento Tridimensional , Síncrotrons , Humanos , Raios X , Orelha Média/diagnóstico por imagem , Ossículos da Orelha/diagnóstico por imagem
4.
J Clin Sleep Med ; 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38415722

RESUMO

STUDY OBJECTIVES: Night-to-night variability of sleep-disordered breathing (SDB) limits the diagnostic accuracy of a single measurement. Multiple recordings using a reliable, affordable method could reduce the uncertainty and avoid misdiagnosis, which could be possible with radar-based home sleep apnea testing (HSAT). METHODS: We recruited consecutive patients with suspected SDB and performed contactless radar-based HSAT with automated scoring (Sleepiz One) over ten nights. During the first night, patients were simultaneously measured with peripheral-arterial tonometry. RESULTS: Twenty-four of the 28 included patients could achieve a minimum of four measurements. The failure rate was 16% (201 of 238 measurements). The apnea-hypopnea index (AHI) and oxygen desaturation index were consistently lower with radar-based HSAT compared to peripheral arterial tonometry. The variability of the AHI was considerable, with a standard error of measurement of 5.2/h (95%CI 4.6-5.7/h) and a minimal detectable difference of 14.4/h (95%CI 12.7-15.9/h). Alcohol consumption partially accounted for the variability, with an AHI increase of 1.7/h (95%CI 0.6-2.8/h) for each standard drink. Based on a single measurement, 17% of patients were misdiagnosed, and 32% were misclassified for SDB severity. After five measurements, the mean AHI of the measured nights stabilized with no evidence of substantial changes with additional measurements. CONCLUSIONS: Night-to-night variability is considerable and stable over ten nights. HSAT using radar-based methods over multiple nights is feasible and well tolerated by patients. It could offer lower costs and allow for multiple-night testing to increase accuracy. However, validation and reducing the failure rate are necessary for implementation in the clinical routine. CLINICAL TRIAL REGISTRATION: "Recording of Multiple Nights Using a New Contactless Device (Sleepiz One Connect) in Obstructive Sleep Apnea", ClinicalTrials.gov, NCT05134402.

6.
Eur Arch Otorhinolaryngol ; 281(3): 1581-1586, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38085305

RESUMO

PURPOSE: This study investigates the impact of the COVID-19 pandemic on complicated upper respiratory tract infections requiring surgical intervention in a tertiary referral center. The aim is to understand the consequences of pandemic-related measures and their subsequent relaxation on the incidence and characteristics of upper respiratory tract infection-related complications. METHODS: Patients who underwent surgery as a complication of upper respiratory tract infections between December 2014 to February 2023 were included. Demographic information, surgical procedures, microbiological findings, and clinical outcomes were assessed and analyzed comparing pre-pandemic, pandemic and post-pandemic groups. RESULTS: 321 patients were enrolled, including 105 patients (32.7%) in the pediatric population. Comparison of pre-pandemic (n = 210), pandemic (n = 46) and post-pandemic periods (n = 65) revealed a statistically significant increase in complicated otologic infections requiring surgical intervention in the post-pandemic period compared to the pandemic period (p value = 0.03). No statistically significant differences in other surgical procedures or demographic parameters were observed. A statistically significant increase in urgent ear surgery in the pediatric population between the pandemic and the post-pandemic period (p value = 0.02) was observed. Beta-hemolytic group A streptococcal infections showed a statistically significant increase in the post-pandemic period compared with the pandemic period (p value = 0.02). CONCLUSIONS: Relaxation of COVID-19-related restrictions was associated with an increase of upper respiratory tract infection-related otologic infections requiring surgical intervention with an increasing rate of beta-hemolytic group A streptococcal infections. These findings highlight the importance of considering the impact of the pandemic on upper respiratory tract infection complications and adapting management strategies accordingly.


Assuntos
COVID-19 , Doenças Nasais , Infecções Respiratórias , Infecções Estreptocócicas , Criança , Humanos , COVID-19/epidemiologia , Pandemias , Infecções Respiratórias/epidemiologia
7.
J Vestib Res ; 34(1): 49-61, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38160379

RESUMO

OBJECTIVE: A normal video Head Impulse Test is the gold standard in the emergency department to rule-in patients with an acute vestibular syndrome and a stroke. We aimed to compare the diagnostic accuracy of vHIT metrics regarding the vestibulo-ocular reflex gain and the corrective saccades in detecting vestibular strokes. METHODS: Prospective cross-sectional study (convenience sample) of patients presenting with acute vestibular syndrome in the emergency department of a tertiary referral centre between February 2015 and May 2020. We screened 1677 patients and enrolled 76 patients fulfilling the inclusion criteria of acute vestibular syndrome. All patients underwent video head impulse test with automated and manual data analysis. A delayed MRI served as a gold standard for vestibular stroke confirmation. RESULTS: Out of 76 patients, 52 were diagnosed with acute unilateral vestibulopathy and 24 with vestibular strokes. The overall accuracy of detecting stroke with an automated vestibulo-ocular reflex gain was 86.8%, compared to 77.6% for cumulative saccade amplitude and automatic saccade mean peak velocity measured by an expert and 71% for cumulative saccade amplitude and saccade mean peak velocity measured automatically. Gain misclassified 13.1% of the patients as false positive or false negative, manual cumulative saccade amplitude and saccade mean peak velocity 22.3%, and automated cumulative saccade amplitude and saccade mean peak velocity 28.9% respectively. CONCLUSIONS: We found a better accuracy of video head impulse test for the diagnosis of vestibular strokes when using the vestibulo-ocular reflex gain than using saccade metrics. Nevertheless, saccades provide an additional and important information for video head impulse test evaluation. The automated saccade detection algorithm is not yet perfect compared to expert analysis, but it may become a valuable tool for future non-expert video head impulse test evaluations.


Assuntos
Movimentos Sacádicos , Acidente Vascular Cerebral , Humanos , Reflexo Vestíbulo-Ocular , Estudos Prospectivos , Estudos Transversais , Teste do Impulso da Cabeça , Vertigem/diagnóstico , Acidente Vascular Cerebral/diagnóstico
8.
Artigo em Inglês | MEDLINE | ID: mdl-38083665

RESUMO

Our study aims to provide basic insights on the impact of the spiral shape of the cochlea, i.e., of geometric torsion and curvature, on wall pressure and wall shear stress. We employed computational fluid dynamics in square duct models with curvature and torsion similar to those found in human cochleae. The results include wall pressures and wall shear stresses within the ducts under oscillating axial flow. Our findings indicate that the helical shape generates higher transverse wall shear stresses compared to exclusively curved or twisted ducts. The wall pressures and transverse wall shear stresses we found rise to amounts that may be physiologically relevant in the cochlea.Clinical relevance- The role of the spiral shape of the cochlea in hearing physiology remains, for a large part, elusive. For a better apprehension of hearing and its disorders, it is important to investigate the influence of geometric properties on biofluids motion and emerging phenomena in the cochlea.


Assuntos
Cóclea , Audição , Humanos , Movimento (Física)
9.
Front Surg ; 10: 1293616, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38098476

RESUMO

Introduction: An optimal placement of bone conduction implants can provide more efficient mechanical transmission to the cochlea if placed in regions with greater bone column density. The aim of this study was to test this hypothesis and to determine the clinical potential of preoperative bone column density assessment for optimal implant placement. Methods: Five complete cadaver heads were scanned with quantitative computed tomography imaging to create topographic maps of bone density based on the column density index (CODI). Laser Doppler vibrometry was used to measure cochlear promontory acceleration under bone conduction stimulation in different locations on the temporal bone, using a bone-anchored hearing aid transducer at frequencies ranging from 355 Hz to 10 kHz. Results: We found a statistically significant association between CODI levels and the accelerance of the cochlear promontory throughout the frequency spectrum, with an average increase of 0.6 dB per unit of CODI. The distance between the transducer and the cochlear promontory had no statistically significant effect on the overall spectrum. Discussion: We highlight the importance of bone column density in relation to the mechanical transmission efficiency of bone conduction implants. It may be worthwhile to consider column density in preoperative planning in clinical practice.

10.
Artigo em Inglês | MEDLINE | ID: mdl-38105363

RESUMO

PURPOSE: To compare the audiological outcomes, tympanic membrane (TM) healing rates and complication rates in patients undergoing endoscopic underlay and over-under tympanoplasty type I (TTI). METHODS: The study includes 95 patients who underwent endoscopic TTI in the period between 2018 and 2023: 56% of the patients had the underlay technique and 41% had the over-under technique. Data regarding pre- and postoperative hearing, perforation characteristics, surgical procedures, graft types and complications were retrospectively analyzed. Audiometrical assessment included air conduction (AC) and bone conduction (BC) pure tone averages (PTA) and air-bone gap (ABG), pre- and postoperatively. RESULTS: Both underlay and over-under techniques significant improved AC PTA, with a mean ABG improvements of 5.9 dB and 7.2 dB, respectively. There was no significant difference in BC PTA between pre- and post-operative, indicating no inner ear damage in both techniques. The over-under technique showed a significantly higher TM closure rate (94.4%) compared to the underlay technique (80.6%). Complications were rare, with only one case of TM lateralization requiring revision surgery. CONCLUSIONS: Endoscopic TTI is an effective treatment in improving auditory function in chronic middle ear diseases. In our cohort, the detachment of the umbo does not negatively influence the postoperative hearing results and does not increase rate of complications. Moreover, the over-under technique demonstrates superior TM closure rates, making it a valuable option for specific cases. However, future prospective studies with larger sample sizes and longer term follow-up are needed to validate these findings and provide more comprehensive insights.

11.
Artigo em Inglês | MEDLINE | ID: mdl-37943315

RESUMO

OBJECTIVES: To assess the prevalence of new hearing losses in patients with acute vestibular syndrome (AVS) and to start to evaluate its diagnostic value for the differentiation between peripheral and central causes. DESIGN: We performed a cross-sectional prospective study in AVS patients presenting to our Emergency Department (ED) from February 2015 to November 2020. All patients received an MRI, Head-impulse test, Nystagmus test and Test of skew ('HINTS'), caloric testing and a pure-tone audiometry. RESULTS: We assessed 71 AVS patients, 17 of whom had a central and 54 a peripheral cause of dizziness. 12.7% had an objective hearing loss. 'HINTS' had an accuracy of 78.9% to diagnose stroke, whereas 'HINTS' plus audiometry 73.2%. 'HINTS' sensitivity was 82.4% and specificity 77.8% compared to 'HINTS' plus audiometry showing a sensitivity of 82.4% and specificity of 70.4%. The four patients with stroke and minor stroke had all central 'HINTS'. 55% of the patients did not perceive their new unilateral hearing loss. CONCLUSIONS: We found that almost one-eighth of the AVS patients had a new onset of hearing loss and only half had self-reported it. 'HINTS' plus audiometry proved to be less accurate to diagnose a central cause than 'HINTS' alone. Audiometry offered little diagnostic accuracy to detect strokes in the ED but might be useful to objectify a new hearing loss that was underestimated in the acute phase. Complete hearing loss should be considered a red flag, as three in four patients suffered from a central cause.

12.
Acta Otolaryngol ; 143(9): 735-741, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37897347

RESUMO

BACKGROUND: Vestibular function (VF) in patients with cochlear implantation (CI) performed during childhood is underinvestigated. OBJECTIVE: To study VF in patients receiving CI during childhood. MATERIAL & METHODS: Sixty patients (22 females) from 7-34 years old, unilaterally (n = 21) and bilaterally (n = 39) implanted, were included. Deafness was congenital (n = 45), consequential to meningitis (n = 3), skull fracture (n = 1), perinatal CMV infection (n = 1), ototoxic drugs (n = 1), unknown etiology (n = 9). VF was measured between 1 to 22 years after implantation, including calorics, v-HIT, c-VEMPS. Dizziness handicap inventory (DHI), age at independent walking(IW), sport activities were also investigated. RESULTS: Nine CI-patients (15%) reported dizziness/vertigo either prior or months to years after surgery. Comparison between symptomatic (15%), asymptomatic (85%), uni-bilaterally CI-patients showed no significant difference on VF's impairment for calorics (p = .603) and v-HIT (p = 1). Symptoms were not related to vestibular impairment. Age at implantation (p = 0.956), uni- bilateral (p = .32), simultaneous versus sequential (p = .134) did not influence IW age. DHI showed a tendency for being symptomatic at higher implantation age. Interval between CI, IWage, current age between surgery and vestibular evaluation did not have a significant effect on symptomatology. CONCLUSION & SIGNIFICANCE: This first middle to long-term evaluation of the VF in CI-patients, implanted in childhood, pointed out that 85% of patients were asymptomatic, with a mean time of >10 years after surgery. Vestibular impairment and symptoms seem to be mainly due to the underlying inner ear's disease rather than surgery.


Assuntos
Implante Coclear , Implantes Cocleares , Feminino , Humanos , Criança , Adolescente , Adulto Jovem , Adulto , Implante Coclear/efeitos adversos , Implantes Cocleares/efeitos adversos , Tontura/diagnóstico , Estudos Prospectivos , Vertigem/etiologia
13.
Audiol Res ; 13(5): 730-740, 2023 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-37887846

RESUMO

OBJECTIVE: The transmastoid plugging of a superior semicircular canal is considered a safe and effective technique for the management of superior semicircular canal dehiscence (SSCD). The aim of this meta-analysis is to assess the postoperative hearing outcomes after the transmastoid plugging of the superior semicircular canal. Search method and data sources: A systematic database search was performed on the following databases until 30 January 2023: MEDLINE, Embase, Cochrane Library, Web of Science, CINAHL, ICTRP, and clinicaltrials.gov. A systematic literature review and meta-analysis of the pooled data were conducted. We also included a consecutive case series with SCDS for those who underwent transmastoid plugging treatment at our clinic. RESULTS: We identified 643 citations and examined 358 full abstracts and 88 full manuscripts. A total of 16 studies were eligible for the systematic review and 11 studies for the meta-analysis. Furthermore, 159 ears (152 patients) were included. The postoperative mean air conduction threshold remained unchanged (mean difference, 2.89 dB; 95% CI: -0.05, 5.84 dB, p = 0.58), while the mean bone conduction threshold was significantly worse (mean difference, -3.53 dB; 95% CI, -6.1, -0.95 dB, p = 0.9). CONCLUSION: The transmastoid plugging technique for superior semicircular canal dehiscence syndrome, although minimally worsening the inner ear threshold, is a safe procedure in terms of hearing preservation and satisfactory symptom relief.

14.
Front Neurol ; 14: 1231403, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37745650

RESUMO

Aim: This study aimed to compare the effectiveness of auditory brainstem response (ABR) and extracochlear electrocochleography (ECochG) in objectively evaluating the coupling efficiency of floating mass transducer (FMT) placement during active middle ear implant (AMEI) surgery. Methods: We enrolled 15 patients (mean age 58.5 ± 19.4 years) with mixed hearing loss who underwent AMEI implantation (seven ossicular chain and eight round window couplings). Before the surgical procedure, an audiogram was performed. We utilized a clinical measurement system to stimulate and record intraoperative ABR and ECochG recordings. The coupling efficiency of the VSB was evaluated through ECochG and ABR threshold measurements. Postoperatively, we conducted an audiogram and a vibrogram. Results: In all 15 patients, ABR threshold testing successfully determined intraoperative coupling efficiency, while ECochG was successful in only eight patients. In our cohort, ABR measurements were more practical, consistent, and robust than ECochG measurements. Coupling efficiency, calculated as the difference between vibrogram thresholds and postoperative bone conduction thresholds, was found to be more accurately predicted by ABR measurements (p = 0.016, R2 = 0.37) than ECochG measurements (p = 0.761, R2 = 0.02). We also found a non-significant trend toward better results with ossicular chain coupling compared to round window coupling. Conclusion: Our findings suggest that ABR measurements are more practical, robust, and consistent than ECochG measurements for determining coupling efficiency during FMT placement surgery. The use of ABR measurements can help to identify the optimal FMT placement, especially with round window coupling. Finally, we offer normative data for both techniques, which can aid other clinical centers in using intraoperative monitoring for AMEI placement.

15.
Front Neurol ; 14: 1181539, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37621854

RESUMO

Introduction: Intracochlear electrocochleography (ECochG) is increasingly being used to measure residual inner ear function in cochlear implant (CI) recipients. ECochG signals reflect the state of the inner ear and can be measured during implantation and post-operatively. The aim of our study was to apply an objective deep learning (DL)-based algorithm to assess the reproducibility of longitudinally recorded ECochG signals, compare them with audiometric hearing thresholds, and identify signal patterns and tonotopic behavior. Methods: We used a previously published objective DL-based algorithm to evaluate post-operative intracochlear ECochG signals collected from 21 ears. The same measurement protocol was repeated three times over 3 months. Additionally, we measured the pure-tone thresholds and subjective loudness estimates for correlation with the objectively detected ECochG signals. Recordings were made on at least four electrodes at three intensity levels. We extracted the electrode positions from computed tomography (CT) scans and used this information to evaluate the tonotopic characteristics of the ECochG responses. Results: The objectively detected ECochG signals exhibited substantial repeatability over a 3-month period (bias-adjusted kappa, 0.68; accuracy 83.8%). Additionally, we observed a moderate-to-strong dependence of the ECochG thresholds on audiometric and subjective hearing levels. Using radiographically determined tonotopic measurement positions, we observed a tendency for tonotopic allocation with a large variance. Furthermore, maximum ECochG amplitudes exhibited a substantial basal shift. Regarding maximal amplitude patterns, most subjects exhibited a flat pattern with amplitudes evenly distributed over the electrode carrier. At higher stimulation frequencies, we observed a shift in the maximum amplitudes toward the basal turn of the cochlea. Conclusions: We successfully implemented an objective DL-based algorithm for evaluating post-operative intracochlear ECochG recordings. We can only evaluate and compare ECochG recordings systematically and independently from experts with an objective analysis. Our results help to identify signal patterns and create a better understanding of the inner ear function with the electrode in place. In the next step, the algorithm can be applied to intra-operative measurements.

16.
Laryngoscope Investig Otolaryngol ; 8(4): 903-911, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37621264

RESUMO

Objective: Sialendoscopy is a minimally invasive diagnostic and therapeutic technique used in the treatment of various salivary gland diseases. To date, there are very few suitable training models other than the pig's head, which has been used at the European Sialendoscopy Training Center for 22 years. The goal of this study was to describe an ovine model for sialendoscopy training and compare the ovine model's to the human anatomy. We propose a step-by-step approach for sialendoscopy training using this ex-vivo model. Methods: The anatomy of the ovine salivary ducts and glands was assessed by magnetic resonance imaging using one fresh ovine head. Thereafter, the model was designed during dissection by an experienced sialendoscopist. The various steps were then validated during consecutive dissections using a Likert-scale questionnaire. Results: The full model was described in the form of a dissection guide and allowed reliable diagnostic sialendoscopy in 10/10 Stenson's and in 5/10 Wharton's ducts. Moreover, interventional sialendoscopy was simulated to provide a training model for the removal of sialoliths in the Stenson's duct. The human and ovine anatomy are quite similar allowing a training experience close to reality. Conclusion: We developed and evaluated an ovine model with the goal of improving training in diagnostic and interventional sialendoscopy. In particular, the Stenson's duct can be successfully prepared, probed and subjected to sialendoscopy. The realistic anatomical environment and excellent tissue quality created a life-like training experience for an experienced sialendoscopist. Further studies with beginners are necessary to validate this model as a training model. Level of Evidence: 4.

17.
Otolaryngol Head Neck Surg ; 169(5): 1276-1281, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37418100

RESUMO

OBJECTIVE: To correlate radiographic evidence of cholesteatoma in the retrotympanum with intraoperative endoscopic findings in cholesteatoma patients and to evaluate the clinical relevance of radiographic evidence of cholesteatoma in the retrotympanum. STUDY DESIGN: Case series with chart review. SETTING: Tertiary referral center. METHODS: Seventy-six consecutive cases undergoing surgical cholesteatoma removal with preoperative high-resolution computed tomography (HRCT) were enrolled in this study. A retrospective analysis of the medical records was conducted. The extension of cholesteatoma regarding different middle ear subspaces, into the antrum and mastoid were reviewed radiologically in preoperative HRCT and endoscopically from surgical videos. Additionally, facial nerve canal dehiscence, infiltration of the middle cranial fossa, and inner ear involvement were documented. RESULTS: Comparison of radiological and endoscopic cholesteatoma extension revealed statistically highly significant overestimation of radiological cholesteatoma extension for all retrotympanic regions (sinus tympani 61.8% vs 19.7%, facial recess 69.7% vs 43.4%, subtympanic sinus 59.2% vs 7.9%, and posterior sinus 72.4% vs 4.0%) and statistically significant overestimation for mesotympanum (82.9% vs 56.6%), hypotympanum (39.5% vs 9.2%), and protympanum (23.7% vs 6.6%). No statistically significant differences were found for epitympanum (98.7% vs 90.8%), antrum (64.5% vs 52.6%), and mastoid (26.3% vs 32.9%). Statistically significant radiological overestimation of facial nerve canal dehiscence (54.0% vs 25.0%) and invasion of tegmen tympani (39.5% vs 19.7%) is reported. CONCLUSION: Radiologic cholesteatoma extension in different middle ear subspaces is overestimated compared to the intraoperative extension. The preoperative relevance of radiological retrotympanic extension might be limited in the choice of approach and transcanal endoscopic approach is always recommended first.


Assuntos
Colesteatoma da Orelha Média , Humanos , Colesteatoma da Orelha Média/diagnóstico por imagem , Colesteatoma da Orelha Média/cirurgia , Estudos Retrospectivos , Orelha Média/diagnóstico por imagem , Orelha Média/cirurgia , Endoscopia/métodos , Tomografia Computadorizada por Raios X
18.
Audiol Res ; 13(3): 459-465, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37366686

RESUMO

BACKGROUND: With the advent of cochlear implants, tactile aids for the profoundly deaf became obsolete decades ago. Nevertheless, they might still be useful in rare cases. We report the case of a 25-year-old woman with Bosley-Salih-Alorainy Syndrome and bilateral cochlear aplasia. METHODS: After it was determined that cochlear or brainstem implants were not an option and tactile aids were not available anymore, a bone conduction device (BCD) on a softband was tried as a tactile aid. The usual retroauricular position and a second position close to the wrist, preferred by the patient, were compared. Sound detection thresholds were measured with and without the aid. Additionally, three bilaterally deaf adult cochlear implant users were tested under the same conditions. RESULTS: At 250-1000 Hz, sounds were perceived as vibrations above approximately 45-60 dB with the device at the wrist. Thresholds were approximately 10 dB poorer when placed retroauricularly. Differentiation between different sounds seemed difficult. Nevertheless, the patient uses the device and can perceive loud sounds. CONCLUSIONS: Cases where the use of tactile aids may make sense are probably very rare. The use of BCD, placed, e.g., at the wrist, may be useful, but sound perception is limited to low frequencies and relatively loud levels.

19.
Front Neurol ; 14: 1183116, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37288065

RESUMO

Introduction and objectives: Maintaining the structural integrity of the cochlea and preserving residual hearing is crucial for patients, especially for those for whom electric acoustic stimulation is intended. Impedances could reflect trauma due to electrode array insertion and therefore could serve as a biomarker for residual hearing. The aim of this study is to evaluate the association between residual hearing and estimated impedance subcomponents in a known collective from an exploratory study. Methods: A total of 42 patients with lateral wall electrode arrays from the same manufacturer were included in the study. For each patient, we used data from audiological measurements to compute residual hearing, impedance telemetry recordings to estimate near and far-field impedances using an approximation model, and computed tomography scans to extract anatomical information about the cochlea. We assessed the association between residual hearing and impedance subcomponent data using linear mixed-effects models. Results: The progression of impedance subcomponents showed that far-field impedance was stable over time compared to near-field impedance. Low-frequency residual hearing demonstrated the progressive nature of hearing loss, with 48% of patients showing full or partial hearing preservation after 6 months of follow-up. Analysis revealed a statistically significant negative effect of near-field impedance on residual hearing (-3.81 dB HL per kΩ; p < 0.001). No significant effect of far-field impedance was found. Conclusion: Our findings suggest that near-field impedance offers higher specificity for residual hearing monitoring, while far-field impedance was not significantly associated with residual hearing. These results highlight the potential of impedance subcomponents as objective biomarkers for outcome monitoring in cochlear implantation.

20.
Ear Hear ; 44(6): 1379-1388, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37157125

RESUMO

OBJECTIVES: Reliable determination of cochlear implant electrode positions shows promise for clinical applications, including anatomy-based fitting of audio processors or monitoring of electrode migration during follow-up. Currently, electrode positioning is measured using radiography. The primary objective of this study is to extend and validate an impedance-based method for estimating electrode insertion depths, which could serve as a radiation-free and cost-effective alternative to radiography. The secondary objective is to evaluate the reliability of the estimation method in the postoperative follow-up over several months. DESIGN: The ground truth insertion depths were measured from postoperative computed tomography scans obtained from the records of 56 cases with an identical lateral wall electrode array. For each of these cases, impedance telemetry records were retrieved starting from the day of implantation up to a maximum observation period of 60 mo. Based on these recordings, the linear and angular electrode insertion depths were estimated using a phenomenological model. The estimates obtained were compared with the ground truth values to calculate the accuracy of the model. RESULTS: Analysis of the long-term recordings using a linear mixed-effects model showed that postoperative tissue resistances remained stable throughout the follow-up period, except for the two most basal electrodes, which increased significantly over time (electrode 11: ~10 Ω/year, electrode 12: ~30 Ω/year). Inferred phenomenological models from early and late impedance telemetry recordings were not different. The insertion depth of all electrodes was estimated with an absolute error of 0.9 mm ± 0.6 mm or 22° ± 18° angle (mean ± SD). CONCLUSIONS: Insertion depth estimations of the model were reliable over time when comparing two postoperative computed tomography scans of the same ear. Our results confirm that the impedance-based position estimation method can be applied to postoperative impedance telemetry recordings. Future work needs to address extracochlear electrode detection to increase the performance of the method.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Impedância Elétrica , Reprodutibilidade dos Testes , Cóclea/cirurgia , Implante Coclear/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...